Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic Adhesiolysis
Objective. To compare the effect of intrauterine suitable balloon (ISB) and Foley balloon (FB) in the prevention of adhesion after hysteroscopic adhesiolysis in patients with intrauterine adhesions (IUAs). Methods. A retrospective study was conducted on 150 women with moderate and severe IUAs, who u...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2018-01-01
|
Series: | BioMed Research International |
Online Access: | http://dx.doi.org/10.1155/2018/9494101 |
id |
doaj-04d8e08f145b41b79d7868aee724bba4 |
---|---|
record_format |
Article |
spelling |
doaj-04d8e08f145b41b79d7868aee724bba42020-11-25T00:05:06ZengHindawi LimitedBioMed Research International2314-61332314-61412018-01-01201810.1155/2018/94941019494101Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic AdhesiolysisRu Zhu0Hua Duan1Lu Gan2Sha Wang3Department of Minimally Invasive Gynecology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing 100006, ChinaDepartment of Minimally Invasive Gynecology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing 100006, ChinaDepartment of Minimally Invasive Gynecology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing 100006, ChinaDepartment of Minimally Invasive Gynecology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing 100006, ChinaObjective. To compare the effect of intrauterine suitable balloon (ISB) and Foley balloon (FB) in the prevention of adhesion after hysteroscopic adhesiolysis in patients with intrauterine adhesions (IUAs). Methods. A retrospective study was conducted on 150 women with moderate and severe IUAs, who underwent hysteroscopic adhesiolysis. According to the postoperative placement of the ISB or FB, the cohort was divided into the ISB group and the FB group. A second-look hysteroscopy was performed at 3 months postsurgery. The scoring system proposed by the American Fertility Society (AFS) was used to evaluate the adhesion during hysteroscopy. Subgroup analysis was carried out based on the degree of IUAs. Results. (1) In the ISB group, only 25% (19/76) women presented adhesion reformation after surgery, while, in the FB group, the adhesion reformation was observed in 35.1% (26/74) patients; however, the difference was not statistically significant (P>0.05). Subsequently, the adhesion reformation rate (29.5%, 13/44) after surgery with an ISB for severe intrauterine adhesions was significantly lower as compared to that (53.6%, 15/28) with FB (P<0.05). (2) In the ISB group, the reduction in the adhesion score after surgery was 8 points, which was significantly higher than the 7 points in the FB group (P<0.05). Conclusion. The ISB is better than the FB in preventing the adhesion reformation and reducing the AFS score after hysteroscopic adhesiolysis in severe IUAs. Also, it can effectively prevent the adhesion reformation in severe IUAs with a similar effect on moderate IUAs.http://dx.doi.org/10.1155/2018/9494101 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ru Zhu Hua Duan Lu Gan Sha Wang |
spellingShingle |
Ru Zhu Hua Duan Lu Gan Sha Wang Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic Adhesiolysis BioMed Research International |
author_facet |
Ru Zhu Hua Duan Lu Gan Sha Wang |
author_sort |
Ru Zhu |
title |
Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic Adhesiolysis |
title_short |
Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic Adhesiolysis |
title_full |
Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic Adhesiolysis |
title_fullStr |
Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic Adhesiolysis |
title_full_unstemmed |
Comparison of Intrauterine Suitable Balloon and Foley Balloon in the Prevention of Adhesion after Hysteroscopic Adhesiolysis |
title_sort |
comparison of intrauterine suitable balloon and foley balloon in the prevention of adhesion after hysteroscopic adhesiolysis |
publisher |
Hindawi Limited |
series |
BioMed Research International |
issn |
2314-6133 2314-6141 |
publishDate |
2018-01-01 |
description |
Objective. To compare the effect of intrauterine suitable balloon (ISB) and Foley balloon (FB) in the prevention of adhesion after hysteroscopic adhesiolysis in patients with intrauterine adhesions (IUAs). Methods. A retrospective study was conducted on 150 women with moderate and severe IUAs, who underwent hysteroscopic adhesiolysis. According to the postoperative placement of the ISB or FB, the cohort was divided into the ISB group and the FB group. A second-look hysteroscopy was performed at 3 months postsurgery. The scoring system proposed by the American Fertility Society (AFS) was used to evaluate the adhesion during hysteroscopy. Subgroup analysis was carried out based on the degree of IUAs. Results. (1) In the ISB group, only 25% (19/76) women presented adhesion reformation after surgery, while, in the FB group, the adhesion reformation was observed in 35.1% (26/74) patients; however, the difference was not statistically significant (P>0.05). Subsequently, the adhesion reformation rate (29.5%, 13/44) after surgery with an ISB for severe intrauterine adhesions was significantly lower as compared to that (53.6%, 15/28) with FB (P<0.05). (2) In the ISB group, the reduction in the adhesion score after surgery was 8 points, which was significantly higher than the 7 points in the FB group (P<0.05). Conclusion. The ISB is better than the FB in preventing the adhesion reformation and reducing the AFS score after hysteroscopic adhesiolysis in severe IUAs. Also, it can effectively prevent the adhesion reformation in severe IUAs with a similar effect on moderate IUAs. |
url |
http://dx.doi.org/10.1155/2018/9494101 |
work_keys_str_mv |
AT ruzhu comparisonofintrauterinesuitableballoonandfoleyballooninthepreventionofadhesionafterhysteroscopicadhesiolysis AT huaduan comparisonofintrauterinesuitableballoonandfoleyballooninthepreventionofadhesionafterhysteroscopicadhesiolysis AT lugan comparisonofintrauterinesuitableballoonandfoleyballooninthepreventionofadhesionafterhysteroscopicadhesiolysis AT shawang comparisonofintrauterinesuitableballoonandfoleyballooninthepreventionofadhesionafterhysteroscopicadhesiolysis |
_version_ |
1725426226713067520 |