Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability Statistics

CRTS III (China Railway Track System III) slab ballastless track structure is one of the high-speed railway ballastless track structures which has Chinese independent intellectual property rights. The mechanical performance of CRTS III slab ballastless track structure under temperature load has not...

Full description

Bibliographic Details
Main Authors: Zhiwu Yu, Ying Xie, Xiuquan Tian
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2019/2975274
id doaj-03eed2f687ec4953b3cee7f5c88b516a
record_format Article
spelling doaj-03eed2f687ec4953b3cee7f5c88b516a2020-11-25T00:20:50ZengHindawi LimitedAdvances in Civil Engineering1687-80861687-80942019-01-01201910.1155/2019/29752742975274Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability StatisticsZhiwu Yu0Ying Xie1Xiuquan Tian2Professor, National Engineering Laboratory for High Speed Railway Construction, Central South University, Changsha, ChinaPh.D. Candidate, Central South University, Changsha, ChinaCentral South University, Changsha, ChinaCRTS III (China Railway Track System III) slab ballastless track structure is one of the high-speed railway ballastless track structures which has Chinese independent intellectual property rights. The mechanical performance of CRTS III slab ballastless track structure under temperature load has not been clear yet. Therefore, through temperature field model and temperature load values selected by statistics analysis based on long-term meteorological data, the mechanical performance of ballastless track structure is studied under two typical working conditions with different safety probability. It is found that the daily extreme values of monthly axial uniform temperature and the daily maximum temperature gradient obey certain statistical laws. In addition, the maximum tensile stress of the self-compacting concrete layer is located in the middle and edge of the slab bottom and the side of the slab. The maximum tensile stress of the base plate is located at the edge of the surface of the layer and the inner edge of the limiting groove. The interface normal tensile stress is located at the end and corner of the interface. Furthermore, maximum stress increases with the increase of safety probability.http://dx.doi.org/10.1155/2019/2975274
collection DOAJ
language English
format Article
sources DOAJ
author Zhiwu Yu
Ying Xie
Xiuquan Tian
spellingShingle Zhiwu Yu
Ying Xie
Xiuquan Tian
Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability Statistics
Advances in Civil Engineering
author_facet Zhiwu Yu
Ying Xie
Xiuquan Tian
author_sort Zhiwu Yu
title Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability Statistics
title_short Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability Statistics
title_full Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability Statistics
title_fullStr Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability Statistics
title_full_unstemmed Research on Mechanical Performance of CRTS III Plate-Type Ballastless Track Structure under Temperature Load Based on Probability Statistics
title_sort research on mechanical performance of crts iii plate-type ballastless track structure under temperature load based on probability statistics
publisher Hindawi Limited
series Advances in Civil Engineering
issn 1687-8086
1687-8094
publishDate 2019-01-01
description CRTS III (China Railway Track System III) slab ballastless track structure is one of the high-speed railway ballastless track structures which has Chinese independent intellectual property rights. The mechanical performance of CRTS III slab ballastless track structure under temperature load has not been clear yet. Therefore, through temperature field model and temperature load values selected by statistics analysis based on long-term meteorological data, the mechanical performance of ballastless track structure is studied under two typical working conditions with different safety probability. It is found that the daily extreme values of monthly axial uniform temperature and the daily maximum temperature gradient obey certain statistical laws. In addition, the maximum tensile stress of the self-compacting concrete layer is located in the middle and edge of the slab bottom and the side of the slab. The maximum tensile stress of the base plate is located at the edge of the surface of the layer and the inner edge of the limiting groove. The interface normal tensile stress is located at the end and corner of the interface. Furthermore, maximum stress increases with the increase of safety probability.
url http://dx.doi.org/10.1155/2019/2975274
work_keys_str_mv AT zhiwuyu researchonmechanicalperformanceofcrtsiiiplatetypeballastlesstrackstructureundertemperatureloadbasedonprobabilitystatistics
AT yingxie researchonmechanicalperformanceofcrtsiiiplatetypeballastlesstrackstructureundertemperatureloadbasedonprobabilitystatistics
AT xiuquantian researchonmechanicalperformanceofcrtsiiiplatetypeballastlesstrackstructureundertemperatureloadbasedonprobabilitystatistics
_version_ 1725365493084192768