A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle Performance

Modern gas turbine firing temperatures (1500−2000 K) are well beyond the maximum allowable blade material temperatures. Continuous safe operation is made possible by cooling the HP turbine first stages, nozzle vanes and rotor blades, with a portion of the compressor discharge air, a practi...

Full description

Bibliographic Details
Main Authors: Roberta Masci, Enrico Sciubba
Format: Article
Language:English
Published: MDPI AG 2019-11-01
Series:International Journal of Turbomachinery, Propulsion and Power
Subjects:
Online Access:https://www.mdpi.com/2504-186X/4/4/36
id doaj-03dc4207164d42249af747f4e2e0a989
record_format Article
spelling doaj-03dc4207164d42249af747f4e2e0a9892020-11-25T01:12:24ZengMDPI AGInternational Journal of Turbomachinery, Propulsion and Power2504-186X2019-11-01443610.3390/ijtpp4040036ijtpp4040036A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle PerformanceRoberta Masci0Enrico Sciubba1Department of Mechanical and Aerospace Engineering, University of Roma Sapienza, 00185 Roma, ItalyDepartment of Mechanical and Aerospace Engineering, University of Roma Sapienza, 00185 Roma, ItalyModern gas turbine firing temperatures (1500−2000 K) are well beyond the maximum allowable blade material temperatures. Continuous safe operation is made possible by cooling the HP turbine first stages, nozzle vanes and rotor blades, with a portion of the compressor discharge air, a practice that induces a penalty on the thermal efficiency cycle. Therefore, a current issue is to investigate the real advantage, technical and economical, of raising maximum temperatures much further beyond current values. In this paper, process simulations of a gas turbine are performed to assess HP turbine first-stage cooling effects on cycle performance. A new simplified and properly streamlined model is proposed for the non-adiabatic expansion of the hot gas mixed with the cooling air within the blade passage, which allows for a comparison of several cycle configurations at different turbine inlet temperatures (TIT) and total turbine expansion ratio (PR) with a realistically acceptable degree of approximation. The calculations suggest that, at a given PR, the TIT can be increased in order to reach a higher cycle efficiency up to a limit imposed by the required amount and temperature of the cooling air. Beyond this limit, no significant gains in thermal efficiency are obtained by adopting higher PR and/or increasing the TIT, so that it is convenient in terms of cycle performance to design at a lower rather than higher PR. The small penalty on cycle efficiency is compensated by the lower plant cost. The results of our model agree with those of some previous and much more complex and computationally expensive studies, so that the novelty of this paper lies in the original method adopted on which the proposed model is based, and in the fast, accurate, and low resource intensity of the corresponding numerical procedure, all advantages that can be crucial for industry needs. The presented analysis is purely thermodynamic and it includes no investigation on the effects of the different configurations on plant costs. Therefore, performing a thermo-economic analysis of the air-cooled gas turbine power plant is the next logical step.https://www.mdpi.com/2504-186X/4/4/36blade coolinggas turbine efficiencytit-expansion ratio for optimal efficiency
collection DOAJ
language English
format Article
sources DOAJ
author Roberta Masci
Enrico Sciubba
spellingShingle Roberta Masci
Enrico Sciubba
A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle Performance
International Journal of Turbomachinery, Propulsion and Power
blade cooling
gas turbine efficiency
tit-expansion ratio for optimal efficiency
author_facet Roberta Masci
Enrico Sciubba
author_sort Roberta Masci
title A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle Performance
title_short A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle Performance
title_full A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle Performance
title_fullStr A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle Performance
title_full_unstemmed A Gas Turbine Cooled-Stage Expansion Model for the Simulation of Blade Cooling Effects on Cycle Performance
title_sort gas turbine cooled-stage expansion model for the simulation of blade cooling effects on cycle performance
publisher MDPI AG
series International Journal of Turbomachinery, Propulsion and Power
issn 2504-186X
publishDate 2019-11-01
description Modern gas turbine firing temperatures (1500−2000 K) are well beyond the maximum allowable blade material temperatures. Continuous safe operation is made possible by cooling the HP turbine first stages, nozzle vanes and rotor blades, with a portion of the compressor discharge air, a practice that induces a penalty on the thermal efficiency cycle. Therefore, a current issue is to investigate the real advantage, technical and economical, of raising maximum temperatures much further beyond current values. In this paper, process simulations of a gas turbine are performed to assess HP turbine first-stage cooling effects on cycle performance. A new simplified and properly streamlined model is proposed for the non-adiabatic expansion of the hot gas mixed with the cooling air within the blade passage, which allows for a comparison of several cycle configurations at different turbine inlet temperatures (TIT) and total turbine expansion ratio (PR) with a realistically acceptable degree of approximation. The calculations suggest that, at a given PR, the TIT can be increased in order to reach a higher cycle efficiency up to a limit imposed by the required amount and temperature of the cooling air. Beyond this limit, no significant gains in thermal efficiency are obtained by adopting higher PR and/or increasing the TIT, so that it is convenient in terms of cycle performance to design at a lower rather than higher PR. The small penalty on cycle efficiency is compensated by the lower plant cost. The results of our model agree with those of some previous and much more complex and computationally expensive studies, so that the novelty of this paper lies in the original method adopted on which the proposed model is based, and in the fast, accurate, and low resource intensity of the corresponding numerical procedure, all advantages that can be crucial for industry needs. The presented analysis is purely thermodynamic and it includes no investigation on the effects of the different configurations on plant costs. Therefore, performing a thermo-economic analysis of the air-cooled gas turbine power plant is the next logical step.
topic blade cooling
gas turbine efficiency
tit-expansion ratio for optimal efficiency
url https://www.mdpi.com/2504-186X/4/4/36
work_keys_str_mv AT robertamasci agasturbinecooledstageexpansionmodelforthesimulationofbladecoolingeffectsoncycleperformance
AT enricosciubba agasturbinecooledstageexpansionmodelforthesimulationofbladecoolingeffectsoncycleperformance
AT robertamasci gasturbinecooledstageexpansionmodelforthesimulationofbladecoolingeffectsoncycleperformance
AT enricosciubba gasturbinecooledstageexpansionmodelforthesimulationofbladecoolingeffectsoncycleperformance
_version_ 1725166616505745408