Comparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellae

Abstract Background Comparing the diagnostic performance of widely used 2D FSE technique (fat-suppressed proton density; FS-PD) and the 3D technique (water-selective cartilage scan; WATS-c) in evaluation of the chondromalacia patella by using arthroscopy as reference standard Results Seventy-five ad...

Full description

Bibliographic Details
Main Authors: Ahmed Ibrahim Tawfik, Wael Hamza Kamr, Saher Ebrahim Taman
Format: Article
Language:English
Published: SpringerOpen 2019-12-01
Series:The Egyptian Journal of Radiology and Nuclear Medicine
Subjects:
Online Access:https://doi.org/10.1186/s43055-019-0102-z
id doaj-03c033dd2edf408999b947ec1424ff68
record_format Article
spelling doaj-03c033dd2edf408999b947ec1424ff682020-12-20T12:34:09ZengSpringerOpenThe Egyptian Journal of Radiology and Nuclear Medicine2090-47622019-12-015011610.1186/s43055-019-0102-zComparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellaeAhmed Ibrahim Tawfik0Wael Hamza Kamr1Saher Ebrahim Taman2Diagnostic Radiology Department, Mansoura UniversityDiagnostic Radiology Department, Mansoura UniversityDiagnostic Radiology Department, Mansoura UniversityAbstract Background Comparing the diagnostic performance of widely used 2D FSE technique (fat-suppressed proton density; FS-PD) and the 3D technique (water-selective cartilage scan; WATS-c) in evaluation of the chondromalacia patella by using arthroscopy as reference standard Results Seventy-five adult patients were enrolled in this study. They underwent MRI examinations then arthroscopy done in 2–4 days after it. MRI was done using 2D (FS-PD) and 3D (WATS-c) sequences and MR images were compared by two radiologists separately, then grading of the cartilage lesions was performed according to modified Noyes grading system and comparison between grade 0–1, 2, and 3 lesions was done using arthroscopic findings as a reference. A false-negative result is considered if there was undergrading of chondromalacia and false-positive result if chondromalacia was overgraded. Each sequence sensitivity, specificity, and accuracy was calculated by both readers. For reader 1, the sensitivity is 69% for WATS-c and 80% for FS-PD and the accuracy is 90% for WATS-c and 92% for FS-PD and for reader 2, the sensitivity is 56% for WATS-c and 84% for FS-PD and the accuracy is 88% for WATS-c and 94% for FS-PD. Conclusion 2D FS-PD images showed better diagnostic performance than 3D WATS-c images for evaluating chondromalacia patella.https://doi.org/10.1186/s43055-019-0102-zWATS-c (water-selective cartilage scan)FS-PD (fat-suppressed proton density)Chondromalacia patella
collection DOAJ
language English
format Article
sources DOAJ
author Ahmed Ibrahim Tawfik
Wael Hamza Kamr
Saher Ebrahim Taman
spellingShingle Ahmed Ibrahim Tawfik
Wael Hamza Kamr
Saher Ebrahim Taman
Comparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellae
The Egyptian Journal of Radiology and Nuclear Medicine
WATS-c (water-selective cartilage scan)
FS-PD (fat-suppressed proton density)
Chondromalacia patella
author_facet Ahmed Ibrahim Tawfik
Wael Hamza Kamr
Saher Ebrahim Taman
author_sort Ahmed Ibrahim Tawfik
title Comparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellae
title_short Comparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellae
title_full Comparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellae
title_fullStr Comparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellae
title_full_unstemmed Comparison of 2D Fat Suppressed Proton Density (FS-PD) and 3D (WATS-c) MRI pulse sequences in evaluation of chondromalacia patellae
title_sort comparison of 2d fat suppressed proton density (fs-pd) and 3d (wats-c) mri pulse sequences in evaluation of chondromalacia patellae
publisher SpringerOpen
series The Egyptian Journal of Radiology and Nuclear Medicine
issn 2090-4762
publishDate 2019-12-01
description Abstract Background Comparing the diagnostic performance of widely used 2D FSE technique (fat-suppressed proton density; FS-PD) and the 3D technique (water-selective cartilage scan; WATS-c) in evaluation of the chondromalacia patella by using arthroscopy as reference standard Results Seventy-five adult patients were enrolled in this study. They underwent MRI examinations then arthroscopy done in 2–4 days after it. MRI was done using 2D (FS-PD) and 3D (WATS-c) sequences and MR images were compared by two radiologists separately, then grading of the cartilage lesions was performed according to modified Noyes grading system and comparison between grade 0–1, 2, and 3 lesions was done using arthroscopic findings as a reference. A false-negative result is considered if there was undergrading of chondromalacia and false-positive result if chondromalacia was overgraded. Each sequence sensitivity, specificity, and accuracy was calculated by both readers. For reader 1, the sensitivity is 69% for WATS-c and 80% for FS-PD and the accuracy is 90% for WATS-c and 92% for FS-PD and for reader 2, the sensitivity is 56% for WATS-c and 84% for FS-PD and the accuracy is 88% for WATS-c and 94% for FS-PD. Conclusion 2D FS-PD images showed better diagnostic performance than 3D WATS-c images for evaluating chondromalacia patella.
topic WATS-c (water-selective cartilage scan)
FS-PD (fat-suppressed proton density)
Chondromalacia patella
url https://doi.org/10.1186/s43055-019-0102-z
work_keys_str_mv AT ahmedibrahimtawfik comparisonof2dfatsuppressedprotondensityfspdand3dwatscmripulsesequencesinevaluationofchondromalaciapatellae
AT waelhamzakamr comparisonof2dfatsuppressedprotondensityfspdand3dwatscmripulsesequencesinevaluationofchondromalaciapatellae
AT saherebrahimtaman comparisonof2dfatsuppressedprotondensityfspdand3dwatscmripulsesequencesinevaluationofchondromalaciapatellae
_version_ 1724376329135063040