EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARING

Purpose: To determine whether the wearing time of contact lenses affects the condition of the meibomian glands and the tear film breakup time. Material and methods: This is a cross-sectional study involving 150 eyes ( 75 patients) with an age between 18 to 65 years. Five groups were allocated, with...

Full description

Bibliographic Details
Main Authors: M. Dimitrova, St. Kostova, A. Vassilev, N. Dakov, B. Irinkova, A. Oscar
Format: Article
Language:English
Published: Trakia University 2019-09-01
Series:Trakia Journal of Sciences
Subjects:
Online Access:http://tru.uni-sz.bg/tsj/Vol.17,%20N3,%202019/M.Dimitrova.pdf
id doaj-03b490d49dc445518360fdede51e7965
record_format Article
spelling doaj-03b490d49dc445518360fdede51e79652021-04-01T08:32:23ZengTrakia UniversityTrakia Journal of Sciences1312-17231313-35512019-09-0117321822310.15547/tjs.2019.03.006EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARINGM. DimitrovaSt. KostovaA. VassilevN. DakovB. Irinkova A. OscarPurpose: To determine whether the wearing time of contact lenses affects the condition of the meibomian glands and the tear film breakup time. Material and methods: This is a cross-sectional study involving 150 eyes ( 75 patients) with an age between 18 to 65 years. Five groups were allocated, with distribution criteria being the soft contact lenses wearing time: up to 5 years, from 6 to 10 years, from 11 to 20 years and more than 20 years. All subjects used soft contact lenses daily, at least 5 hours a day and 4 days a week. All patients underwent a thorough ophthalmic examination and non invasive tear film breakup time (NIBUT), and meibomian gland loss (MGL) investigated with Oculus Keratograph 5 M. Results: A statistically significant relation with the soft contact lenses wearing time has been found for the indicator MGL,% (U) (p = 0.025). In the general study of male and female patients, a significant association was only observed in female patients (p = 0.04). A statistically significant relation to the soft contact lenses wearing time has been found for the indicators NIBUT 1, s ( P=0.035) и NIBUT Av, s ( P=0.023). The same relation has been found only in female patients - NIBUT 1, s ( P=0.035] и NIBUT Av, s ( P=0.023). Conclusion: Long-term contact lenses wearing is proportional to the change in gland function and may contribute to the development of dry eye syndrome. http://tru.uni-sz.bg/tsj/Vol.17,%20N3,%202019/M.Dimitrova.pdfcontact lens discomfortmeibomian glandstear film break up timedry eye syndrom
collection DOAJ
language English
format Article
sources DOAJ
author M. Dimitrova
St. Kostova
A. Vassilev
N. Dakov
B. Irinkova
A. Oscar
spellingShingle M. Dimitrova
St. Kostova
A. Vassilev
N. Dakov
B. Irinkova
A. Oscar
EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARING
Trakia Journal of Sciences
contact lens discomfort
meibomian glands
tear film break up time
dry eye syndrom
author_facet M. Dimitrova
St. Kostova
A. Vassilev
N. Dakov
B. Irinkova
A. Oscar
author_sort M. Dimitrova
title EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARING
title_short EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARING
title_full EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARING
title_fullStr EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARING
title_full_unstemmed EVALUATION OF MEIBOMIAN GLANDS LOSS AND TEAR FILM BREAKUP TIME IN PATIENTS WITH VARYING PERIOD OF SOFT CONTACT LENSES WEARING
title_sort evaluation of meibomian glands loss and tear film breakup time in patients with varying period of soft contact lenses wearing
publisher Trakia University
series Trakia Journal of Sciences
issn 1312-1723
1313-3551
publishDate 2019-09-01
description Purpose: To determine whether the wearing time of contact lenses affects the condition of the meibomian glands and the tear film breakup time. Material and methods: This is a cross-sectional study involving 150 eyes ( 75 patients) with an age between 18 to 65 years. Five groups were allocated, with distribution criteria being the soft contact lenses wearing time: up to 5 years, from 6 to 10 years, from 11 to 20 years and more than 20 years. All subjects used soft contact lenses daily, at least 5 hours a day and 4 days a week. All patients underwent a thorough ophthalmic examination and non invasive tear film breakup time (NIBUT), and meibomian gland loss (MGL) investigated with Oculus Keratograph 5 M. Results: A statistically significant relation with the soft contact lenses wearing time has been found for the indicator MGL,% (U) (p = 0.025). In the general study of male and female patients, a significant association was only observed in female patients (p = 0.04). A statistically significant relation to the soft contact lenses wearing time has been found for the indicators NIBUT 1, s ( P=0.035) и NIBUT Av, s ( P=0.023). The same relation has been found only in female patients - NIBUT 1, s ( P=0.035] и NIBUT Av, s ( P=0.023). Conclusion: Long-term contact lenses wearing is proportional to the change in gland function and may contribute to the development of dry eye syndrome.
topic contact lens discomfort
meibomian glands
tear film break up time
dry eye syndrom
url http://tru.uni-sz.bg/tsj/Vol.17,%20N3,%202019/M.Dimitrova.pdf
work_keys_str_mv AT mdimitrova evaluationofmeibomianglandslossandtearfilmbreakuptimeinpatientswithvaryingperiodofsoftcontactlenseswearing
AT stkostova evaluationofmeibomianglandslossandtearfilmbreakuptimeinpatientswithvaryingperiodofsoftcontactlenseswearing
AT avassilev evaluationofmeibomianglandslossandtearfilmbreakuptimeinpatientswithvaryingperiodofsoftcontactlenseswearing
AT ndakov evaluationofmeibomianglandslossandtearfilmbreakuptimeinpatientswithvaryingperiodofsoftcontactlenseswearing
AT birinkova evaluationofmeibomianglandslossandtearfilmbreakuptimeinpatientswithvaryingperiodofsoftcontactlenseswearing
AT aoscar evaluationofmeibomianglandslossandtearfilmbreakuptimeinpatientswithvaryingperiodofsoftcontactlenseswearing
_version_ 1724176559931129856