A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency

A vortex flow meter employs a sensor based on the piezoelectric vibration principle to realize vortex signal acquisition, and therefore the measurement results are susceptible to vibration noise. In this paper, the generalized mode method is proposed based on the central tendency characteristic of t...

Full description

Bibliographic Details
Main Authors: Bin Li, Chengyi Wang, Jie Chen
Format: Article
Language:English
Published: MDPI AG 2020-09-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/18/5379
id doaj-03941f68528248c09205eeb55abf1628
record_format Article
spelling doaj-03941f68528248c09205eeb55abf16282020-11-25T03:13:22ZengMDPI AGSensors1424-82202020-09-01205379537910.3390/s20185379A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central TendencyBin Li0Chengyi Wang1Jie Chen2School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, ChinaSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, ChinaSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, ChinaA vortex flow meter employs a sensor based on the piezoelectric vibration principle to realize vortex signal acquisition, and therefore the measurement results are susceptible to vibration noise. In this paper, the generalized mode method is proposed based on the central tendency characteristic of the vortex signal and combined with the existing filter bank method. The method combining filter bank with the generalized mode is designed and applied in the signal-processing system of the vortex flow meter, which makes up for the defect that the filter bank method cannot filter out the noise in the sub-band. The simulation experiments verify the feasibility and anti-interference performance of the algorithm. Meanwhile, a comparison with two FFT (Fast Fourier Transform) spectrum analysis methods shows that the algorithm designed in this paper requires a smaller sample size and achieves better real-time performance. The actual anti-vibration experiment and calibration experiment verify that the signal-processing system of a vortex flow meter ensures good accuracy and repeatability.https://www.mdpi.com/1424-8220/20/18/5379vortex flow sensorsignal processingcentral tendency
collection DOAJ
language English
format Article
sources DOAJ
author Bin Li
Chengyi Wang
Jie Chen
spellingShingle Bin Li
Chengyi Wang
Jie Chen
A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency
Sensors
vortex flow sensor
signal processing
central tendency
author_facet Bin Li
Chengyi Wang
Jie Chen
author_sort Bin Li
title A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency
title_short A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency
title_full A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency
title_fullStr A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency
title_full_unstemmed A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency
title_sort frequency-correcting method for a vortex flow sensor signal based on a central tendency
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2020-09-01
description A vortex flow meter employs a sensor based on the piezoelectric vibration principle to realize vortex signal acquisition, and therefore the measurement results are susceptible to vibration noise. In this paper, the generalized mode method is proposed based on the central tendency characteristic of the vortex signal and combined with the existing filter bank method. The method combining filter bank with the generalized mode is designed and applied in the signal-processing system of the vortex flow meter, which makes up for the defect that the filter bank method cannot filter out the noise in the sub-band. The simulation experiments verify the feasibility and anti-interference performance of the algorithm. Meanwhile, a comparison with two FFT (Fast Fourier Transform) spectrum analysis methods shows that the algorithm designed in this paper requires a smaller sample size and achieves better real-time performance. The actual anti-vibration experiment and calibration experiment verify that the signal-processing system of a vortex flow meter ensures good accuracy and repeatability.
topic vortex flow sensor
signal processing
central tendency
url https://www.mdpi.com/1424-8220/20/18/5379
work_keys_str_mv AT binli afrequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency
AT chengyiwang afrequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency
AT jiechen afrequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency
AT binli frequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency
AT chengyiwang frequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency
AT jiechen frequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency
_version_ 1724647210134536192