A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency
A vortex flow meter employs a sensor based on the piezoelectric vibration principle to realize vortex signal acquisition, and therefore the measurement results are susceptible to vibration noise. In this paper, the generalized mode method is proposed based on the central tendency characteristic of t...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-09-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/20/18/5379 |
id |
doaj-03941f68528248c09205eeb55abf1628 |
---|---|
record_format |
Article |
spelling |
doaj-03941f68528248c09205eeb55abf16282020-11-25T03:13:22ZengMDPI AGSensors1424-82202020-09-01205379537910.3390/s20185379A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central TendencyBin Li0Chengyi Wang1Jie Chen2School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, ChinaSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, ChinaSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, ChinaA vortex flow meter employs a sensor based on the piezoelectric vibration principle to realize vortex signal acquisition, and therefore the measurement results are susceptible to vibration noise. In this paper, the generalized mode method is proposed based on the central tendency characteristic of the vortex signal and combined with the existing filter bank method. The method combining filter bank with the generalized mode is designed and applied in the signal-processing system of the vortex flow meter, which makes up for the defect that the filter bank method cannot filter out the noise in the sub-band. The simulation experiments verify the feasibility and anti-interference performance of the algorithm. Meanwhile, a comparison with two FFT (Fast Fourier Transform) spectrum analysis methods shows that the algorithm designed in this paper requires a smaller sample size and achieves better real-time performance. The actual anti-vibration experiment and calibration experiment verify that the signal-processing system of a vortex flow meter ensures good accuracy and repeatability.https://www.mdpi.com/1424-8220/20/18/5379vortex flow sensorsignal processingcentral tendency |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Bin Li Chengyi Wang Jie Chen |
spellingShingle |
Bin Li Chengyi Wang Jie Chen A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency Sensors vortex flow sensor signal processing central tendency |
author_facet |
Bin Li Chengyi Wang Jie Chen |
author_sort |
Bin Li |
title |
A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency |
title_short |
A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency |
title_full |
A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency |
title_fullStr |
A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency |
title_full_unstemmed |
A Frequency-Correcting Method for a Vortex Flow Sensor Signal Based on a Central Tendency |
title_sort |
frequency-correcting method for a vortex flow sensor signal based on a central tendency |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2020-09-01 |
description |
A vortex flow meter employs a sensor based on the piezoelectric vibration principle to realize vortex signal acquisition, and therefore the measurement results are susceptible to vibration noise. In this paper, the generalized mode method is proposed based on the central tendency characteristic of the vortex signal and combined with the existing filter bank method. The method combining filter bank with the generalized mode is designed and applied in the signal-processing system of the vortex flow meter, which makes up for the defect that the filter bank method cannot filter out the noise in the sub-band. The simulation experiments verify the feasibility and anti-interference performance of the algorithm. Meanwhile, a comparison with two FFT (Fast Fourier Transform) spectrum analysis methods shows that the algorithm designed in this paper requires a smaller sample size and achieves better real-time performance. The actual anti-vibration experiment and calibration experiment verify that the signal-processing system of a vortex flow meter ensures good accuracy and repeatability. |
topic |
vortex flow sensor signal processing central tendency |
url |
https://www.mdpi.com/1424-8220/20/18/5379 |
work_keys_str_mv |
AT binli afrequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency AT chengyiwang afrequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency AT jiechen afrequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency AT binli frequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency AT chengyiwang frequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency AT jiechen frequencycorrectingmethodforavortexflowsensorsignalbasedonacentraltendency |
_version_ |
1724647210134536192 |