Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter

LCL filter has been widely used in the grid connected inverter, since it is effective in attenuation of the switching frequency harmonics in the inverter. However, the resonance in this filter causes stability problems and must be damped effectively to achieve stability. There are some methods to da...

Full description

Bibliographic Details
Main Authors: Mohammad Alshiekh, Alaa Marouf, Muhieddin Kubeitari
Format: Article
Language:English
Published: Hindawi Limited 2020-01-01
Series:Journal of Control Science and Engineering
Online Access:http://dx.doi.org/10.1155/2020/3164601
id doaj-0375c25fed5f4427a5c4685bda950acb
record_format Article
spelling doaj-0375c25fed5f4427a5c4685bda950acb2020-11-25T03:07:53ZengHindawi LimitedJournal of Control Science and Engineering1687-52491687-52572020-01-01202010.1155/2020/31646013164601Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected InverterMohammad Alshiekh0Alaa Marouf1Muhieddin Kubeitari2Department of Electrical Engineering, Higher Institute for Applied Sciences and Technology (HIAST), Damascus, SyriaDepartment of Electrical Engineering, Higher Institute for Applied Sciences and Technology (HIAST), Damascus, SyriaDepartment of Electrical Engineering, Higher Institute for Applied Sciences and Technology (HIAST), Damascus, SyriaLCL filter has been widely used in the grid connected inverter, since it is effective in attenuation of the switching frequency harmonics in the inverter. However, the resonance in this filter causes stability problems and must be damped effectively to achieve stability. There are some methods to damp the resonance; one method is passive damping of resonance by adding a series resistor with the filter capacitor, but passive element reduces the inverter efficiency. Other method uses active damping (AD) by adding a proportional control loop of filter capacitor current, but this method needs additional sensor to measure filter capacitor current; moreover, when the control loops are digitally implemented, the computation delay in AD control loop will lead to some difficulties in choosing control parameters and maintaining system stability. This paper presents current control scheme for the grid connected inverter with the LCL filter. The proposed scheme ensures the control of injected current into grid with AD of the resonance in the LCL filter while keeping system stability and eliminating the effect of computation delay of the AD loop. An estimation of filter capacitor current with one step ahead is performed using the discrete time observer based on measuring the injected current. This reduces the cost and increases the robustness of the system. Proportional Resonant (PR) controller is used to control the injected current. Design of control system and choosing its parameters are studied and justified in details to ensure suitable performance with adequate stability margins. Simulation and experimental results show the effectiveness and the robustness of the proposed control scheme.http://dx.doi.org/10.1155/2020/3164601
collection DOAJ
language English
format Article
sources DOAJ
author Mohammad Alshiekh
Alaa Marouf
Muhieddin Kubeitari
spellingShingle Mohammad Alshiekh
Alaa Marouf
Muhieddin Kubeitari
Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter
Journal of Control Science and Engineering
author_facet Mohammad Alshiekh
Alaa Marouf
Muhieddin Kubeitari
author_sort Mohammad Alshiekh
title Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter
title_short Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter
title_full Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter
title_fullStr Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter
title_full_unstemmed Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter
title_sort current control and active damping for single phase lcl-filtered grid connected inverter
publisher Hindawi Limited
series Journal of Control Science and Engineering
issn 1687-5249
1687-5257
publishDate 2020-01-01
description LCL filter has been widely used in the grid connected inverter, since it is effective in attenuation of the switching frequency harmonics in the inverter. However, the resonance in this filter causes stability problems and must be damped effectively to achieve stability. There are some methods to damp the resonance; one method is passive damping of resonance by adding a series resistor with the filter capacitor, but passive element reduces the inverter efficiency. Other method uses active damping (AD) by adding a proportional control loop of filter capacitor current, but this method needs additional sensor to measure filter capacitor current; moreover, when the control loops are digitally implemented, the computation delay in AD control loop will lead to some difficulties in choosing control parameters and maintaining system stability. This paper presents current control scheme for the grid connected inverter with the LCL filter. The proposed scheme ensures the control of injected current into grid with AD of the resonance in the LCL filter while keeping system stability and eliminating the effect of computation delay of the AD loop. An estimation of filter capacitor current with one step ahead is performed using the discrete time observer based on measuring the injected current. This reduces the cost and increases the robustness of the system. Proportional Resonant (PR) controller is used to control the injected current. Design of control system and choosing its parameters are studied and justified in details to ensure suitable performance with adequate stability margins. Simulation and experimental results show the effectiveness and the robustness of the proposed control scheme.
url http://dx.doi.org/10.1155/2020/3164601
work_keys_str_mv AT mohammadalshiekh currentcontrolandactivedampingforsinglephaselclfilteredgridconnectedinverter
AT alaamarouf currentcontrolandactivedampingforsinglephaselclfilteredgridconnectedinverter
AT muhieddinkubeitari currentcontrolandactivedampingforsinglephaselclfilteredgridconnectedinverter
_version_ 1715298247459733504