Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation

Pulmonary vein isolation (PVI) is the cornerstone therapy of atrial fibrillation (AF). Radiofrequency catheter ablation (RFCA) is performed using a point-by-point method to achieve durable PVI. However, this procedure remains complex and time-consuming, and the long-term clinical outcomes are still...

Full description

Bibliographic Details
Main Authors: Xuerong Sun, Jiang Lu, Jinxuan Lin, Tianjie Feng, Ni Suo, Lihui Zheng, Zhimin Liu, Gang Chen, Xiaohan Fan, Shu Zhang, Guodong Niu
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Cardiology Research and Practice
Online Access:http://dx.doi.org/10.1155/2021/8821467
id doaj-030c985599084cb8b4e12d5a1ab72650
record_format Article
spelling doaj-030c985599084cb8b4e12d5a1ab726502021-03-01T01:14:23ZengHindawi LimitedCardiology Research and Practice2090-05972021-01-01202110.1155/2021/8821467Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial FibrillationXuerong Sun0Jiang Lu1Jinxuan Lin2Tianjie Feng3Ni Suo4Lihui Zheng5Zhimin Liu6Gang Chen7Xiaohan Fan8Shu Zhang9Guodong Niu10Arrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterArrhythmia CenterPulmonary vein isolation (PVI) is the cornerstone therapy of atrial fibrillation (AF). Radiofrequency catheter ablation (RFCA) is performed using a point-by-point method to achieve durable PVI. However, this procedure remains complex and time-consuming, and the long-term clinical outcomes are still not satisfactory. Recently, there has been increasing interest in the clinical application of high-power short-duration (HPSD) approaches in the field of RFCA. HPSD ablation, distinguishing it from the conventional ablation strategy, delivers RF energy at a high power and saves the dwell time at each site. It is unknown whether the HPSD approach can bring some gratifying changes in the field of RF energy ablation. A number of experimental studies and clinical studies have been conducted regarding this topic. The review aimed to summarize the research findings and evaluate the procedural efficiency, safety, and clinical outcomes of the HPSD approach based on the evidence available to date.http://dx.doi.org/10.1155/2021/8821467
collection DOAJ
language English
format Article
sources DOAJ
author Xuerong Sun
Jiang Lu
Jinxuan Lin
Tianjie Feng
Ni Suo
Lihui Zheng
Zhimin Liu
Gang Chen
Xiaohan Fan
Shu Zhang
Guodong Niu
spellingShingle Xuerong Sun
Jiang Lu
Jinxuan Lin
Tianjie Feng
Ni Suo
Lihui Zheng
Zhimin Liu
Gang Chen
Xiaohan Fan
Shu Zhang
Guodong Niu
Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
Cardiology Research and Practice
author_facet Xuerong Sun
Jiang Lu
Jinxuan Lin
Tianjie Feng
Ni Suo
Lihui Zheng
Zhimin Liu
Gang Chen
Xiaohan Fan
Shu Zhang
Guodong Niu
author_sort Xuerong Sun
title Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
title_short Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
title_full Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
title_fullStr Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
title_full_unstemmed Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
title_sort efficiency, safety, and efficacy of high-power short-duration radiofrequency ablation in patients with atrial fibrillation
publisher Hindawi Limited
series Cardiology Research and Practice
issn 2090-0597
publishDate 2021-01-01
description Pulmonary vein isolation (PVI) is the cornerstone therapy of atrial fibrillation (AF). Radiofrequency catheter ablation (RFCA) is performed using a point-by-point method to achieve durable PVI. However, this procedure remains complex and time-consuming, and the long-term clinical outcomes are still not satisfactory. Recently, there has been increasing interest in the clinical application of high-power short-duration (HPSD) approaches in the field of RFCA. HPSD ablation, distinguishing it from the conventional ablation strategy, delivers RF energy at a high power and saves the dwell time at each site. It is unknown whether the HPSD approach can bring some gratifying changes in the field of RF energy ablation. A number of experimental studies and clinical studies have been conducted regarding this topic. The review aimed to summarize the research findings and evaluate the procedural efficiency, safety, and clinical outcomes of the HPSD approach based on the evidence available to date.
url http://dx.doi.org/10.1155/2021/8821467
work_keys_str_mv AT xuerongsun efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT jianglu efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT jinxuanlin efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT tianjiefeng efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT nisuo efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT lihuizheng efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT zhiminliu efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT gangchen efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT xiaohanfan efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT shuzhang efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
AT guodongniu efficiencysafetyandefficacyofhighpowershortdurationradiofrequencyablationinpatientswithatrialfibrillation
_version_ 1714842287973859328