Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probe
The proposal of investigations of soft organic soils in a new calibration chamber performed at the Rzeszow University of Technology has been presented in this paper. The unique feature of this chamber is the possibility of simultaneous soil testing with the use of two penetrometers: FVT (Field Vane...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://doi.org/10.1051/e3sconf/20184900109 |
id |
doaj-02f081abbd944d75968aceba4d22b9c7 |
---|---|
record_format |
Article |
spelling |
doaj-02f081abbd944d75968aceba4d22b9c72021-04-02T08:25:42ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01490010910.1051/e3sconf/20184900109e3sconf_solina2018_00109Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probeStraż GrzegorzThe proposal of investigations of soft organic soils in a new calibration chamber performed at the Rzeszow University of Technology has been presented in this paper. The unique feature of this chamber is the possibility of simultaneous soil testing with the use of two penetrometers: FVT (Field Vane Test) and DPL (Dynamic Probing Light). It has been possible due to the large size of the cylindrical soil sample: 62.5 cm in diameter and max. 80 cm high. Additionally, a construction with a new calibration chamber has been described, concerning potential capabilities and restrictions when conducting researches. The presented calibration chamber ensures the stability of the parameters set during the tests, which allows one to compare the test results and search for the relationship between the analyzed parameters. Shear strength from the FVT test was adopted as reference. The results of preliminary research were presented and a detailed research plan was prepared, which will be implemented in the next stages of the investigations.https://doi.org/10.1051/e3sconf/20184900109 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Straż Grzegorz |
spellingShingle |
Straż Grzegorz Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probe E3S Web of Conferences |
author_facet |
Straż Grzegorz |
author_sort |
Straż Grzegorz |
title |
Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probe |
title_short |
Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probe |
title_full |
Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probe |
title_fullStr |
Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probe |
title_full_unstemmed |
Preliminary investigations of organics soil in a new calibration chamber with the use of the FVT and DPL probe |
title_sort |
preliminary investigations of organics soil in a new calibration chamber with the use of the fvt and dpl probe |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2018-01-01 |
description |
The proposal of investigations of soft organic soils in a new calibration chamber performed at the Rzeszow University of Technology has been presented in this paper. The unique feature of this chamber is the possibility of simultaneous soil testing with the use of two penetrometers: FVT (Field Vane Test) and DPL (Dynamic Probing Light). It has been possible due to the large size of the cylindrical soil sample: 62.5 cm in diameter and max. 80 cm high. Additionally, a construction with a new calibration chamber has been described, concerning potential capabilities and restrictions when conducting researches. The presented calibration chamber ensures the stability of the parameters set during the tests, which allows one to compare the test results and search for the relationship between the analyzed parameters. Shear strength from the FVT test was adopted as reference. The results of preliminary research were presented and a detailed research plan was prepared, which will be implemented in the next stages of the investigations. |
url |
https://doi.org/10.1051/e3sconf/20184900109 |
work_keys_str_mv |
AT strazgrzegorz preliminaryinvestigationsoforganicssoilinanewcalibrationchamberwiththeuseofthefvtanddplprobe |
_version_ |
1724170418876579840 |