Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination Procedure

In this study, the effect of base-band measurement setup errors on DPD performance was investigated and a calibration procedure is developed to eliminate the measurement errors. A base-band measurement setup is prepared at laboratory with instruments and then the data which is measured and the deter...

Full description

Bibliographic Details
Main Authors: A. H. Yüzer, E. B. Şanlı
Format: Article
Language:English
Published: Advanced Electromagnetics 2017-11-01
Series:Advanced Electromagnetics
Subjects:
Online Access:https://aemjournal.org/index.php/AEM/article/view/584
id doaj-02a750b447954ddcb934b4f5208cbe05
record_format Article
spelling doaj-02a750b447954ddcb934b4f5208cbe052020-11-25T00:09:55ZengAdvanced ElectromagneticsAdvanced Electromagnetics2119-02752017-11-0164525710.7716/aem.v6i4.584584Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination ProcedureA. H. Yüzer0E. B. Şanlı1Karabük University/Electrical and Electronics EngineeringDepartment of Mechatronics Engineering, Karabuk University ,Karabuk, TurkeyIn this study, the effect of base-band measurement setup errors on DPD performance was investigated and a calibration procedure is developed to eliminate the measurement errors. A base-band measurement setup is prepared at laboratory with instruments and then the data which is measured and the deteriorating effect of errors on Digital Predistortion (DPD) linearization performance are investigated. In order to eliminate deteriorating effect of this error a three steps calibration procedure is developed. Before and after calibration application DPD performance is measured. It is showed both in simulation and experimentally that the calibration procedure improved the DPD system linearization performance from 10 dB to 26dB and 13dB to 20dB, respectively.https://aemjournal.org/index.php/AEM/article/view/584base-band measurementDigital Predistortion
collection DOAJ
language English
format Article
sources DOAJ
author A. H. Yüzer
E. B. Şanlı
spellingShingle A. H. Yüzer
E. B. Şanlı
Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination Procedure
Advanced Electromagnetics
base-band measurement
Digital Predistortion
author_facet A. H. Yüzer
E. B. Şanlı
author_sort A. H. Yüzer
title Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination Procedure
title_short Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination Procedure
title_full Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination Procedure
title_fullStr Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination Procedure
title_full_unstemmed Effect of the Base-band Measurement Setup Errors on DPD Performance and Elimination Procedure
title_sort effect of the base-band measurement setup errors on dpd performance and elimination procedure
publisher Advanced Electromagnetics
series Advanced Electromagnetics
issn 2119-0275
publishDate 2017-11-01
description In this study, the effect of base-band measurement setup errors on DPD performance was investigated and a calibration procedure is developed to eliminate the measurement errors. A base-band measurement setup is prepared at laboratory with instruments and then the data which is measured and the deteriorating effect of errors on Digital Predistortion (DPD) linearization performance are investigated. In order to eliminate deteriorating effect of this error a three steps calibration procedure is developed. Before and after calibration application DPD performance is measured. It is showed both in simulation and experimentally that the calibration procedure improved the DPD system linearization performance from 10 dB to 26dB and 13dB to 20dB, respectively.
topic base-band measurement
Digital Predistortion
url https://aemjournal.org/index.php/AEM/article/view/584
work_keys_str_mv AT ahyuzer effectofthebasebandmeasurementsetuperrorsondpdperformanceandeliminationprocedure
AT ebsanlı effectofthebasebandmeasurementsetuperrorsondpdperformanceandeliminationprocedure
_version_ 1725410139320614912