Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights

Objective. To study and analyze the changes of intervertebral foramen height and area of the degenerative L4-5 intervertebral disc under different pushing heights by the finite element method. Methods. CT and MRI images of T12-S1 segments were obtained from a healthy volunteer who met the inclusion...

Full description

Bibliographic Details
Main Authors: Huaili Ding, Lijun Liao, Peichun Yan, Xiaolin Zhao, Min Li
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Journal of Healthcare Engineering
Online Access:http://dx.doi.org/10.1155/2021/1322397
id doaj-026718752c524f2c9a3b80bb65dea26a
record_format Article
spelling doaj-026718752c524f2c9a3b80bb65dea26a2021-08-02T00:00:01ZengHindawi LimitedJournal of Healthcare Engineering2040-23092021-01-01202110.1155/2021/1322397Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing HeightsHuaili Ding0Lijun Liao1Peichun Yan2Xiaolin Zhao3Min Li4Fujian Maternity and Children’s HospitalFujian Maternity and Children’s HospitalFujian Maternity and Children’s HospitalFujian Maternity and Children’s HospitalFujian Maternity and Children’s HospitalObjective. To study and analyze the changes of intervertebral foramen height and area of the degenerative L4-5 intervertebral disc under different pushing heights by the finite element method. Methods. CT and MRI images of T12-S1 segments were obtained from a healthy volunteer who met the inclusion criteria. A DR machine was used to capture images of the lumbar lateral section before and after simultaneous pushing of the L4 and L5 spinous processes by manipulation called Daogaijinbei, and the measurement showed that the displacement changes of L4 and L5 were both approximately 10 cm, so the pushing height was set at 0–10 cm. A three-dimensional finite element model of the entire normal lumbar spine was established using Mimics 16.0, Geomagic Studio 2014, Hypermesh 13.0, MSC.Patran 2012, and so on. The disc height and nucleus area of the lumbar disc of the normal entire lumbar disc model were adjusted to establish models of the L4-5 disc with mild, moderate, and severe degeneration. Changes of disc height and area of the L4-5 degenerative intervertebral disc under different pushing heights were calculated. Results. The size of the L4-5 intervertebral foramen was analyzed from the height and area of the intervertebral foramen, and the results showed the following: (1) as for the normal lumbar disc and a lumbar of the L4-5 disc with mild and moderate degeneration, the height of the L4-5 intervertebral foramen and its area both increased during pushing between 0 and 8 cm. After the pushing height reached 8 cm, the height and area of the L4-5 intervertebral foramen gradually became stable; (2) as for the L4-5 disc with severe degeneration, during the process of pushing, the height and area of the L4-5 intervertebral foramen increased slightly, but this change was not obvious. Conclusions. After the spinal manipulation, the sizes of the L4-5 intervertebral foramen of the L4-5 disc with mild and moderate degeneration were significantly larger than those before pushing; in contrast, the size of L4-5 intervertebral foramen of the L4-5 disc with severe lumbar degeneration was not significantly changed.http://dx.doi.org/10.1155/2021/1322397
collection DOAJ
language English
format Article
sources DOAJ
author Huaili Ding
Lijun Liao
Peichun Yan
Xiaolin Zhao
Min Li
spellingShingle Huaili Ding
Lijun Liao
Peichun Yan
Xiaolin Zhao
Min Li
Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights
Journal of Healthcare Engineering
author_facet Huaili Ding
Lijun Liao
Peichun Yan
Xiaolin Zhao
Min Li
author_sort Huaili Ding
title Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights
title_short Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights
title_full Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights
title_fullStr Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights
title_full_unstemmed Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights
title_sort three-dimensional finite element analysis of l4-5 degenerative lumbar disc traction under different pushing heights
publisher Hindawi Limited
series Journal of Healthcare Engineering
issn 2040-2309
publishDate 2021-01-01
description Objective. To study and analyze the changes of intervertebral foramen height and area of the degenerative L4-5 intervertebral disc under different pushing heights by the finite element method. Methods. CT and MRI images of T12-S1 segments were obtained from a healthy volunteer who met the inclusion criteria. A DR machine was used to capture images of the lumbar lateral section before and after simultaneous pushing of the L4 and L5 spinous processes by manipulation called Daogaijinbei, and the measurement showed that the displacement changes of L4 and L5 were both approximately 10 cm, so the pushing height was set at 0–10 cm. A three-dimensional finite element model of the entire normal lumbar spine was established using Mimics 16.0, Geomagic Studio 2014, Hypermesh 13.0, MSC.Patran 2012, and so on. The disc height and nucleus area of the lumbar disc of the normal entire lumbar disc model were adjusted to establish models of the L4-5 disc with mild, moderate, and severe degeneration. Changes of disc height and area of the L4-5 degenerative intervertebral disc under different pushing heights were calculated. Results. The size of the L4-5 intervertebral foramen was analyzed from the height and area of the intervertebral foramen, and the results showed the following: (1) as for the normal lumbar disc and a lumbar of the L4-5 disc with mild and moderate degeneration, the height of the L4-5 intervertebral foramen and its area both increased during pushing between 0 and 8 cm. After the pushing height reached 8 cm, the height and area of the L4-5 intervertebral foramen gradually became stable; (2) as for the L4-5 disc with severe degeneration, during the process of pushing, the height and area of the L4-5 intervertebral foramen increased slightly, but this change was not obvious. Conclusions. After the spinal manipulation, the sizes of the L4-5 intervertebral foramen of the L4-5 disc with mild and moderate degeneration were significantly larger than those before pushing; in contrast, the size of L4-5 intervertebral foramen of the L4-5 disc with severe lumbar degeneration was not significantly changed.
url http://dx.doi.org/10.1155/2021/1322397
work_keys_str_mv AT huailiding threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights
AT lijunliao threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights
AT peichunyan threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights
AT xiaolinzhao threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights
AT minli threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights
_version_ 1721245409936932864