Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation

Abstract In-vitro mechanical indentation experimentation is performed on bulk liver tissue of lamb to characterize its nonlinear material behaviour. The material response is characterized by a visco-hyperelastic material model by the use of 2-dimensional inverse finite element (FE) analysis. The tim...

Full description

Bibliographic Details
Main Authors: Rajeswara R. Resapu, Roger D. Bradshaw
Format: Article
Language:English
Published: Springer 2021-04-01
Series:SN Applied Sciences
Subjects:
Online Access:https://doi.org/10.1007/s42452-021-04577-6
id doaj-024030ba24784d6facdf3be549fe2216
record_format Article
spelling doaj-024030ba24784d6facdf3be549fe22162021-04-25T11:20:57ZengSpringerSN Applied Sciences2523-39632523-39712021-04-01351910.1007/s42452-021-04577-6Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentationRajeswara R. Resapu0Roger D. Bradshaw1Department of Mechanical Engineering, GITAM (Deemed To Be University)Department of Mechanical Engineering, University of LouisvilleAbstract In-vitro mechanical indentation experimentation is performed on bulk liver tissue of lamb to characterize its nonlinear material behaviour. The material response is characterized by a visco-hyperelastic material model by the use of 2-dimensional inverse finite element (FE) analysis. The time-dependent behaviour is characterized by the viscoelastic model represented by a 4-parameter Prony series, whereas the large deformations are modelled using the hyperelastic Neo-Hookean model. The shear response described by the initial and final shear moduli and the corresponding Prony series parameters are optimized using ANSYS with the Root Mean Square (RMS) error being the objective function. Optimized material properties are validated using experimental results obtained under different loading histories. To study the efficacy of a 2D model, a three dimensional (3D) model of the specimen is developed using Micro-CT of the specimen. The initial elastic modulus of the lamb liver obtained was found to 13.5 kPa for 5% indentation depth at a loading rate of 1 mm/sec for 1-cycle. These properties are able to predict the response at 8.33% depth and a loading rate of 5 mm/sec at multiple cycles with reasonable accuracy. Article highlights The visco-hyperelastic model accurately models the large displacement as well as the time-dependent behaviour of the bulk liver tissue. Mapped meshing of the 3D FE model saves computational time and captures localized displacement in an accurate manner. The 2D axisymmetric model while predicting the force response of the bulk tissue, cannot predict the localized deformations.https://doi.org/10.1007/s42452-021-04577-6Shear responseANSYSNonlinearLoading rateMapped mesh
collection DOAJ
language English
format Article
sources DOAJ
author Rajeswara R. Resapu
Roger D. Bradshaw
spellingShingle Rajeswara R. Resapu
Roger D. Bradshaw
Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
SN Applied Sciences
Shear response
ANSYS
Nonlinear
Loading rate
Mapped mesh
author_facet Rajeswara R. Resapu
Roger D. Bradshaw
author_sort Rajeswara R. Resapu
title Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
title_short Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
title_full Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
title_fullStr Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
title_full_unstemmed Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
title_sort application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
publisher Springer
series SN Applied Sciences
issn 2523-3963
2523-3971
publishDate 2021-04-01
description Abstract In-vitro mechanical indentation experimentation is performed on bulk liver tissue of lamb to characterize its nonlinear material behaviour. The material response is characterized by a visco-hyperelastic material model by the use of 2-dimensional inverse finite element (FE) analysis. The time-dependent behaviour is characterized by the viscoelastic model represented by a 4-parameter Prony series, whereas the large deformations are modelled using the hyperelastic Neo-Hookean model. The shear response described by the initial and final shear moduli and the corresponding Prony series parameters are optimized using ANSYS with the Root Mean Square (RMS) error being the objective function. Optimized material properties are validated using experimental results obtained under different loading histories. To study the efficacy of a 2D model, a three dimensional (3D) model of the specimen is developed using Micro-CT of the specimen. The initial elastic modulus of the lamb liver obtained was found to 13.5 kPa for 5% indentation depth at a loading rate of 1 mm/sec for 1-cycle. These properties are able to predict the response at 8.33% depth and a loading rate of 5 mm/sec at multiple cycles with reasonable accuracy. Article highlights The visco-hyperelastic model accurately models the large displacement as well as the time-dependent behaviour of the bulk liver tissue. Mapped meshing of the 3D FE model saves computational time and captures localized displacement in an accurate manner. The 2D axisymmetric model while predicting the force response of the bulk tissue, cannot predict the localized deformations.
topic Shear response
ANSYS
Nonlinear
Loading rate
Mapped mesh
url https://doi.org/10.1007/s42452-021-04577-6
work_keys_str_mv AT rajeswararresapu applicationofmicrocomputertomographyandinversefiniteelementanalysisforcharacterizingtheviscohyperelasticresponseofbulklivertissueusingindentation
AT rogerdbradshaw applicationofmicrocomputertomographyandinversefiniteelementanalysisforcharacterizingtheviscohyperelasticresponseofbulklivertissueusingindentation
_version_ 1721509784631377920