SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY
The paper presents the outcome of the Moldovan power system static stability modeling and analysis, considering the operation in parallel with the Ukrainian power system and the established operation regimes. The analysis includes verification of the reserve of static stability and definition of the...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Academy of Sciences of Moldova
2013-04-01
|
Series: | Problems of the Regional Energetics |
Subjects: | |
Online Access: | http://journal.ie.asm.md/assets/files/m71_2_226.pdf |
id |
doaj-0219f9dea6c04249889f7de0b42e70ce |
---|---|
record_format |
Article |
spelling |
doaj-0219f9dea6c04249889f7de0b42e70ce2020-11-24T22:43:53ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702013-04-012013-11(21)113 SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITYPostolaty V.M.0Golub I.V.1Institute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaThe paper presents the outcome of the Moldovan power system static stability modeling and analysis, considering the operation in parallel with the Ukrainian power system and the established operation regimes. The analysis includes verification of the reserve of static stability and definition of the static stability limits for a given operation mode, and the determination of the power system stability domain of the controlled system nodes. Parameters used for the analysis are the active power flows via controlled sections and the voltage levels at the controlled system nodes. Two options of Moldovan power system scheme are considered: a single-circuit transit Dniester HPP - Balti - Straseni – Chisinau 330kV and a double-circuit transit. Studies have shown that the implementation of the double-circuit transit would lead to better static stability parameters and lower power system losses. The analysis has been carried out based on the power system stability.http://journal.ie.asm.md/assets/files/m71_2_226.pdfstatic stabilityaenergy system regim |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Postolaty V.M. Golub I.V. |
spellingShingle |
Postolaty V.M. Golub I.V. SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY Problems of the Regional Energetics static stability a energy system regim |
author_facet |
Postolaty V.M. Golub I.V. |
author_sort |
Postolaty V.M. |
title |
SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY |
title_short |
SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY |
title_full |
SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY |
title_fullStr |
SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY |
title_full_unstemmed |
SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY |
title_sort |
simulation of the transitional regime of the moldovan power under static stability |
publisher |
Academy of Sciences of Moldova |
series |
Problems of the Regional Energetics |
issn |
1857-0070 |
publishDate |
2013-04-01 |
description |
The paper presents the outcome of the Moldovan power system static stability modeling and analysis, considering the operation in parallel with the Ukrainian power system and the established operation regimes. The analysis includes verification of the reserve of static stability and definition of the static stability limits for a given operation mode, and the determination of the power system stability domain of the controlled system nodes. Parameters used for the analysis are the active power flows via controlled sections and the voltage levels at the controlled system nodes. Two options of Moldovan power system scheme are considered: a single-circuit transit Dniester HPP - Balti - Straseni – Chisinau 330kV and a double-circuit transit. Studies have shown that the implementation of the double-circuit transit would lead to better static stability parameters and lower power system losses. The analysis has been carried out based on the power system stability. |
topic |
static stability a energy system regim |
url |
http://journal.ie.asm.md/assets/files/m71_2_226.pdf |
work_keys_str_mv |
AT postolatyvm simulationofthetransitionalregimeofthemoldovanpowerunderstaticstability AT golubiv simulationofthetransitionalregimeofthemoldovanpowerunderstaticstability |
_version_ |
1725693979850178560 |