SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY

The paper presents the outcome of the Moldovan power system static stability modeling and analysis, considering the operation in parallel with the Ukrainian power system and the established operation regimes. The analysis includes verification of the reserve of static stability and definition of the...

Full description

Bibliographic Details
Main Authors: Postolaty V.M., Golub I.V.
Format: Article
Language:English
Published: Academy of Sciences of Moldova 2013-04-01
Series:Problems of the Regional Energetics
Subjects:
a
Online Access:http://journal.ie.asm.md/assets/files/m71_2_226.pdf
id doaj-0219f9dea6c04249889f7de0b42e70ce
record_format Article
spelling doaj-0219f9dea6c04249889f7de0b42e70ce2020-11-24T22:43:53ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702013-04-012013-11(21)113 SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITYPostolaty V.M.0Golub I.V.1Institute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaThe paper presents the outcome of the Moldovan power system static stability modeling and analysis, considering the operation in parallel with the Ukrainian power system and the established operation regimes. The analysis includes verification of the reserve of static stability and definition of the static stability limits for a given operation mode, and the determination of the power system stability domain of the controlled system nodes. Parameters used for the analysis are the active power flows via controlled sections and the voltage levels at the controlled system nodes. Two options of Moldovan power system scheme are considered: a single-circuit transit Dniester HPP - Balti - Straseni – Chisinau 330kV and a double-circuit transit. Studies have shown that the implementation of the double-circuit transit would lead to better static stability parameters and lower power system losses. The analysis has been carried out based on the power system stability.http://journal.ie.asm.md/assets/files/m71_2_226.pdfstatic stabilityaenergy system regim
collection DOAJ
language English
format Article
sources DOAJ
author Postolaty V.M.
Golub I.V.
spellingShingle Postolaty V.M.
Golub I.V.
SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY
Problems of the Regional Energetics
static stability
a
energy system regim
author_facet Postolaty V.M.
Golub I.V.
author_sort Postolaty V.M.
title SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY
title_short SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY
title_full SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY
title_fullStr SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY
title_full_unstemmed SIMULATION OF THE TRANSITIONAL REGIME OF THE MOLDOVAN POWER UNDER STATIC STABILITY
title_sort simulation of the transitional regime of the moldovan power under static stability
publisher Academy of Sciences of Moldova
series Problems of the Regional Energetics
issn 1857-0070
publishDate 2013-04-01
description The paper presents the outcome of the Moldovan power system static stability modeling and analysis, considering the operation in parallel with the Ukrainian power system and the established operation regimes. The analysis includes verification of the reserve of static stability and definition of the static stability limits for a given operation mode, and the determination of the power system stability domain of the controlled system nodes. Parameters used for the analysis are the active power flows via controlled sections and the voltage levels at the controlled system nodes. Two options of Moldovan power system scheme are considered: a single-circuit transit Dniester HPP - Balti - Straseni – Chisinau 330kV and a double-circuit transit. Studies have shown that the implementation of the double-circuit transit would lead to better static stability parameters and lower power system losses. The analysis has been carried out based on the power system stability.
topic static stability
a
energy system regim
url http://journal.ie.asm.md/assets/files/m71_2_226.pdf
work_keys_str_mv AT postolatyvm simulationofthetransitionalregimeofthemoldovanpowerunderstaticstability
AT golubiv simulationofthetransitionalregimeofthemoldovanpowerunderstaticstability
_version_ 1725693979850178560