A New Design Method for Industrial Portal Frames in Fire

Industrial portal frames near to other buildings must keep their vertical walls standing in fire in order to prevent fire spread.  A recently developed analysis, implemented in the program Vulcan, using a combination of static and dynamic solvers, has shown that the strong base connections recommend...

Full description

Bibliographic Details
Main Authors: Y. Song, Z. Huang, I. Burgess, R. Plank
Format: Article
Language:English
Published: CTU Central Library 2009-01-01
Series:Acta Polytechnica
Subjects:
Online Access:https://ojs.cvut.cz/ojs/index.php/ap/article/view/1093