Monitoring of the Cooling System via Thermal Parameters
The cooling system, including the thermal grease, heatsinks, plays an important role in the power converters for its reliable operation. While in the long-term operation situation, the cooling system will degrade with different kinds of failure mechanism of the components and finally result in the d...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2019-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8844653/ |
id |
doaj-009223094dce4625a0273ba1382090bc |
---|---|
record_format |
Article |
spelling |
doaj-009223094dce4625a0273ba1382090bc2021-03-29T23:07:57ZengIEEEIEEE Access2169-35362019-01-01713811013812110.1109/ACCESS.2019.29423268844653Monitoring of the Cooling System via Thermal ParametersShuai Zheng0Xiong Du1https://orcid.org/0000-0002-0212-1653Jun Zhang2Yaoyi Yu3State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaState Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaState Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaState Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaThe cooling system, including the thermal grease, heatsinks, plays an important role in the power converters for its reliable operation. While in the long-term operation situation, the cooling system will degrade with different kinds of failure mechanism of the components and finally result in the damage to the power converters. In this paper, the method was proposed to monitor the thermal network parameters of the cooling system using the cooling curves of junction temperature. By establishing the relationship between the RC parameters of Cauer network and time constants of cooling curves, the thermal parameters about cooling system can be obtained. Experimental tests are performed to verify the accuracy of proposed method. Results indicate the degradation state of the cooling system can be evaluated by monitoring the variation of thermal network parameters of the cooling system.https://ieeexplore.ieee.org/document/8844653/Cauer thermal network modelcooling systemthermal network parameters |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Shuai Zheng Xiong Du Jun Zhang Yaoyi Yu |
spellingShingle |
Shuai Zheng Xiong Du Jun Zhang Yaoyi Yu Monitoring of the Cooling System via Thermal Parameters IEEE Access Cauer thermal network model cooling system thermal network parameters |
author_facet |
Shuai Zheng Xiong Du Jun Zhang Yaoyi Yu |
author_sort |
Shuai Zheng |
title |
Monitoring of the Cooling System via Thermal Parameters |
title_short |
Monitoring of the Cooling System via Thermal Parameters |
title_full |
Monitoring of the Cooling System via Thermal Parameters |
title_fullStr |
Monitoring of the Cooling System via Thermal Parameters |
title_full_unstemmed |
Monitoring of the Cooling System via Thermal Parameters |
title_sort |
monitoring of the cooling system via thermal parameters |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2019-01-01 |
description |
The cooling system, including the thermal grease, heatsinks, plays an important role in the power converters for its reliable operation. While in the long-term operation situation, the cooling system will degrade with different kinds of failure mechanism of the components and finally result in the damage to the power converters. In this paper, the method was proposed to monitor the thermal network parameters of the cooling system using the cooling curves of junction temperature. By establishing the relationship between the RC parameters of Cauer network and time constants of cooling curves, the thermal parameters about cooling system can be obtained. Experimental tests are performed to verify the accuracy of proposed method. Results indicate the degradation state of the cooling system can be evaluated by monitoring the variation of thermal network parameters of the cooling system. |
topic |
Cauer thermal network model cooling system thermal network parameters |
url |
https://ieeexplore.ieee.org/document/8844653/ |
work_keys_str_mv |
AT shuaizheng monitoringofthecoolingsystemviathermalparameters AT xiongdu monitoringofthecoolingsystemviathermalparameters AT junzhang monitoringofthecoolingsystemviathermalparameters AT yaoyiyu monitoringofthecoolingsystemviathermalparameters |
_version_ |
1724189944644108288 |