Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value
This paper will focus on the study and identifying various threshold values for two commonly used edge detection techniques, which are Sobel and Canny Edge detection. The idea is to determine which values are apt in giving accurate results in identifying a particular leukemic cell. In addition, eval...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2017-01-01
|
Series: | EPJ Web of Conferences |
Online Access: | https://doi.org/10.1051/epjconf/201716201074 |
id |
doaj-002b19235b9d4a04bde02111727964c9 |
---|---|
record_format |
Article |
spelling |
doaj-002b19235b9d4a04bde02111727964c92021-08-02T16:02:59ZengEDP SciencesEPJ Web of Conferences2100-014X2017-01-011620107410.1051/epjconf/201716201074epjconf_incape2017_01074Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold valueAbdul Salam Afifah SalmiMd. Isa Mohd. NazrinAhmad Muhammad ImranChe Ismail RizalafandeThis paper will focus on the study and identifying various threshold values for two commonly used edge detection techniques, which are Sobel and Canny Edge detection. The idea is to determine which values are apt in giving accurate results in identifying a particular leukemic cell. In addition, evaluating suitability of edge detectors are also essential as feature extraction of the cell depends greatly on image segmentation (edge detection). Firstly, an image of M7 subtype of Acute Myelocytic Leukemia (AML) is chosen due to its diagnosing which were found lacking. Next, for an enhancement in image quality, noise filters are applied. Hence, by comparing images with no filter, median and average filter, useful information can be acquired. Each threshold value is fixed with value 0, 0.25 and 0.5. From the investigation found, without any filter, Canny with a threshold value of 0.5 yields the best result.https://doi.org/10.1051/epjconf/201716201074 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Abdul Salam Afifah Salmi Md. Isa Mohd. Nazrin Ahmad Muhammad Imran Che Ismail Rizalafande |
spellingShingle |
Abdul Salam Afifah Salmi Md. Isa Mohd. Nazrin Ahmad Muhammad Imran Che Ismail Rizalafande Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value EPJ Web of Conferences |
author_facet |
Abdul Salam Afifah Salmi Md. Isa Mohd. Nazrin Ahmad Muhammad Imran Che Ismail Rizalafande |
author_sort |
Abdul Salam Afifah Salmi |
title |
Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value |
title_short |
Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value |
title_full |
Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value |
title_fullStr |
Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value |
title_full_unstemmed |
Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value |
title_sort |
comparison of edge detection techniques for m7 subtype leukemic cell in terms of noise filters and threshold value |
publisher |
EDP Sciences |
series |
EPJ Web of Conferences |
issn |
2100-014X |
publishDate |
2017-01-01 |
description |
This paper will focus on the study and identifying various threshold values for two commonly used edge detection techniques, which are Sobel and Canny Edge detection. The idea is to determine which values are apt in giving accurate results in identifying a particular leukemic cell. In addition, evaluating suitability of edge detectors are also essential as feature extraction of the cell depends greatly on image segmentation (edge detection). Firstly, an image of M7 subtype of Acute Myelocytic Leukemia (AML) is chosen due to its diagnosing which were found lacking. Next, for an enhancement in image quality, noise filters are applied. Hence, by comparing images with no filter, median and average filter, useful information can be acquired. Each threshold value is fixed with value 0, 0.25 and 0.5. From the investigation found, without any filter, Canny with a threshold value of 0.5 yields the best result. |
url |
https://doi.org/10.1051/epjconf/201716201074 |
work_keys_str_mv |
AT abdulsalamafifahsalmi comparisonofedgedetectiontechniquesform7subtypeleukemiccellintermsofnoisefiltersandthresholdvalue AT mdisamohdnazrin comparisonofedgedetectiontechniquesform7subtypeleukemiccellintermsofnoisefiltersandthresholdvalue AT ahmadmuhammadimran comparisonofedgedetectiontechniquesform7subtypeleukemiccellintermsofnoisefiltersandthresholdvalue AT cheismailrizalafande comparisonofedgedetectiontechniquesform7subtypeleukemiccellintermsofnoisefiltersandthresholdvalue |
_version_ |
1721230082290221056 |